Download PDF
Weed Zapper Start Up Instructions
- Always startup on “Low Weed” selection.
- Select the HP selection that is just below your tractors rated HP.
- Install all insulator arms, wires, according to instructional
YouTube video
- Only hook up center HV cable to center section of front
electrodes At this time, leave both ends of all “small gray wing
transfer wires” disconnected.
- Start the center section only 1st. Do this by satisfying all safety’s
on the right side of the monitor run screen. This is including
generator rpm over 1650 (1000 + PTO RPM’S). The RED
“Disabled” light that is below the vertical column of safety boxes
should turn to GREEN “Ready” once safety’s and rpm’s are
satisfied.
- Once you see “Zapper is Running!” displayed on the lower right
corner of the monitor you may shock a weed, if there are any
present.
- If no warnings or fault codes display on monitor during this
startup, then connect both ends of the Main wing transfer wire’s
and repeat the entire process.
- If no warnings or fault codes display on monitor during this
startup, then connect both ends of the Outer wing transfer wire’s
and repeat the entire process.
This is a 2 step process on the 20’ and 30’ with single left
and right wings and is a 3 step process on the 40’ booms.